Fire Safety for Healthcare Premises - Structural Fire Protection Provision - Part 18

Posted by LWF: 16/04/2018 11:28

In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 17, the potential for an escape route for staff only which incorporates a flat roof was discussed. In part 18, we talk about sub-compartmentation and the reasons it can be found in healthcare venues.

As mentioned earlier in this blog series, compartmentation is the division of area by fire-protected walls, floors etc. in order to limit the spread of smoke and fire from one compartment to the next. 

Sub-compartmentation is necessary because although some compartment sizes allowed under HTM 05-02 are permitted in terms of fire containment on a general basis, such large compartments are unsuitable where patient-access areas are involved. The reason for this is that many patients could be accommodated in a compartment and if a fire were to develop, all could be severely affected by smoke and toxic gas inhalation and the spread of fire itself.

For the well-being of the patients, it is therefore important that the areas are divided into sub-compartments to limit those who may be affected.

In addition, if a fire develops in a compartment or sub-compartment, staff assisted evacuation will be required into the next compartment or sub-compartment, which would be an immense task if the compartment occupant capacity was too great.

The criteria for sub-compartmentation of a compartment is comprised of three parts – where the floor area is greater than 750 m2, or where a compartment contains a department where 30 or more patients will have access simultaneously, or where sleeping accommodation is provided for more than 30 patients.

In the case of hospital outpatient departments, the overall compartment floor area may be increased to 1000 m2 before sub-compartmentation is necessary. It is likely that those patients attending an out-patient department will have more mobility and sleeping accommodation will not be provided.

Sub-compartment walls should be fire resistant to a minimum of 30 minutes and should terminate at the underside of a compartment floor or roof to ensure there are no gaps through which fire can spread or smoke can pass.

Each sub-compartment should have a minimum of two exits to adjoining but separate compartments or sub-compartments to ensure escape is possible if a fire were to start blocking one exit and that the occupants can be moved to a compartment with a full 30 minutes of fire resistance from the compartment of fire origin.

In part 19, travel distances will be discussed. In the meantime, if you have any queries about fire safety in healthcare premises or wish to discuss this blog series, please contact Peter Gyere in the first instance on 0208 668 8663.

Lawrence Webster Forrest is a fire engineering consultancy based in Surrey with over 25 years' experience, which provides a wide range of consultancy services to professionals involved in the design, development and construction and operation of buildings. 

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Halocarbon Agents - Part 12

    In LWF’s fire engineering blog series for architects and others in the building design business, we have been looking at Fire Suppression and most recently, gaseous systems. In part 11, we looked at the effect of gases on the environment and in part 12, we’ll discuss halocarbon agents and inert agents before touching on water mist systems.Halocarbon agentsHalocarbon agents were developed as a viable alternative to halons after the substance was banned for...

    Read more...

  • Fire Safety for Healthcare Premises - Thermoplastic Materials - Part 31

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 30, we discussed the potential for internal fire spread and in part 31, we take a look at the use of thermoplastic materials in roof lights and lighting diffusers.In part 30, the national and European classifications for linings within spaces contained in healthcare buildings were detailed. The...

    Read more...

  • Facilities Management & Fire Safety - Taking action upon finding a fire - Part 5

    In LWF’s blog series for those who work in Facilities Management, or who have an interest in or responsibility for fire safety, we have been looking at fire procedures; who they are written for and how they should be written.  Parts 3 and 4 of this series looked at summoning the fire service to a fire and in part 5, we look at what other action should be taken upon fire discovery.The issue of...

    Read more...

  • Fire Safety for Healthcare Premises - Internal Fire Spread - Part 30

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 29 of this series, we looked at plant areas and how they should be designed with safe evacuation in mind. In part 30, we discuss the potential for fire to spread through internal walls and how this...

    Read more...

  • Fire Engineering Design and Risk Assessment - Agents used in Gaseous Systems - Part 11

    In LWF’s Fire Engineering and Risk Assessment blog series for architects and others in the building design business, we have been looking at gaseous systems as a method of fire suppression. In part 10 of this series, the required configuration of gaseous systems was outlined and in part 11, the agents used in such systems will be discussed from the point of view of safety and the environment.After the banning of halon 1301 for...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London