Fire Safety for Healthcare Premises - In-Patient Mental Health & Learning Disability Facilities continued - Part 12

Posted by LWF: 08/03/2018 11:26

In LWF’s blog series for healthcare professionals to give advice and information on best practice of fire safety in hospitals and other healthcare premises. In part 11, we discussed the necessity of adhering to specific design requirements for fire safety in in-patient mental health and learning disability facilities and the necessity of access and egress for patients with restricted mobility, as well as the potential for moving patients on their beds as a part of evacuation. In part 12, the separation of areas which are accessed by patients from other parts of the healthcare premises is considered.

As a part of the general requirement in healthcare premises to facilitate progressive horizontal evacuation, there is a necessity to minimise the likelihood of fire starting in non-patient areas which could affect or spread to patient-access areas. 

As per the guidance given in HTM 05-02, non-patient access areas are divided into the following categorisations:

Hazard departments – departments or management units which contain high fire loads and/or noted ignition sources. Hazardous departments should be separated physically and by distance from patient-access areas and must not be adjacent, either horizontally or vertically unless precautions have been taken which provide additional and adequate fire protection. Such protection may take the form of construction which is fire-resistant to an enhanced level and duration.

Non-hazard departments – consists of departments or management units which do not contain the hazards indicated in the first category. Such areas may be planned adjacently to patient access areas, provided they are separated by fire-resistant compartment walls and floors.

Patient access areas must always be in a separate compartment to non-patient access areas. HTM 05-02 includes a table which gives guidance on the protection which should be given to specific areas and departments/management units. As a rough guide, in a normal dependency situation, there should be 60+ minute fire-resisting construction between patient and non-patient access areas, plus in many areas, there will be a necessity for active fire auto-suppression. In very high dependency areas, the vast majority of non-patient access areas are not allowed to be adjacent to patient accessed areas at all. Each situation must be assessed fully and the relevant guidances adhered to.

Part 13 of this series will continue to look at inpatient mental health & learning disability facilities, starting with how staffing levels should be organised and giving guidance on the FSO’s definition of a ‘responsible person’. In the meantime, if you have any queries about fire safety in healthcare premises or wish to discuss this blog series, please contact Peter Gyere in the first instance on 0208 668 8663.

Lawrence Webster Forrest is a fire engineering consultancy based in Surrey with over 25 years' experience, which provides a wide range of consultancy services to professionals involved in the design, development and construction and operation of buildings. 

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Firefighting & The Fire Service - Part 18

    In LWF's Fire Engineering blog series for Architects and others involved in building design, we have been looking at firefighting. In part 17, we began to look at how firefighting is undertaken by the Fire Service and their objectives and modes of operation when arriving at a fire. In part 19, tactical firefighting is discussed.While the general objectives of tactical firefighting were given in the last blog, there are various methods used by firefighters...

    Read more...

  • Fire Safety for Healthcare Premises - Open-sided Car Parks - Part 52

    In LWFs blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 51 of this series, we were looking at the potential for fire spread from one area of a building to another through external surfaces, before moving on to begin to look at the necessary arrangements for car parks. In part 52, we continue on that theme by considering...

    Read more...

  • Facilities Management & Fire Safety - Calculating RSET - Part 9

    In LWFs blog series for those who work in Facilities Management or who have an interest in or responsibility for fire safety we have been looking at fire safety engineering. In part 8, we looked at how ASET (Available Safe Egress Time) is calculated and how this should always be more than the RSET (Required Safe Egress Time). While ASET involves a series of calculations relating to fire growth and the building itself, RSET, also...

    Read more...

  • Fire Engineering Design and Risk Assessment - Firefighting & The Fire Service - Part 17

    In LWF’s fire engineering blog series for Architects and others in the business of building design, we have been looking at firefighting. In part 16, we discussed first-aid firefighting by the occupancy and the use of hose reels to do so. In part 17, we will begin to look at firefighting from the point of view of the Fire Services.The particular objectives of the Fire Service in a given situation will be decided upon...

    Read more...

  • Fire Safety for Healthcare Premises - External Fire Spread - Part 51

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 50 of this series, we discussed the potential for external fire spread including calculating unprotected areas and consideration of the surfaces of external walls and roofs. In part 51, we continue looking at external fire spread, starting with junctions of different elements.At the junction of wall and...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London