Lawrence Webster Forrest (LWF), Fire Engineering and Fire Risk Management Consultants
Lawrence Webster Forrest (LWF), Fire Engineering and Fire Risk Management Consultants



Navigation

Client login
Forgotten password
Follow us on Twitter Follow us on Facebook Subscribe to our blog

Lawrence Webster Forrest
Legion House
Lower Road
Kenley
Surrey
CR8 5NH

Tel: +44 (0)20 8668 8663 Fax: +44 (0)20 8668 8583
E-mail: fire@lwf.co.uk

Fire Safety for Healthcare Premises - In-Patient Mental Health & Learning Disability Facilities continued - Part 11

Posted by LWF: 01/03/2018 11:17

Fire Safety for Healthcare premises is a blog series by LWF which aims to give guidance on healthcare-based standards and best practice in fire safety. In part 10 of this series, the additional fire safety measures required for in-patient mental health and learning disability facilities was outlined, particularly in relation to the dual demands of fire safety and security. In part 11, specific design requirements for such facilities are considered.

In order to protect sleeping patients, sleeping and day quarters should be compartmented separately. Sleeping accommodation should comprise bedrooms, bathrooms/WCs, cleaners room, a small office for overnight duty staff and linen storage only. Any other elements of the department must be in other compartments.

Sleeping quarters should be sub-compartmented and each sub-compartment should contain no more than 10 beds, including any swing bed provision (short-term use beds). 

If swing beds may be moved between male and female sub-compartments, the number in each must number no more than 10.

Where it is necessary to maintain segregation of patients during an evacuation, the routes should be designed with such processes in mind. This process should also be taken into account in the design of secure places of safety from fire outside the building and after evacuation.

All bedrooms must be classed as fire hazard rooms and where it is necessary to have rooms which can be locked from the inside, the doors must be fitted with a lock not requiring a key. Any door which can be locked from the inside must be accessible by staff with a standard key, to avoid any delays in opening the door in a fire situation.

As in the case of all healthcare facilities, some patients who have restricted mobility may require moving on their beds and evacuation routes must take the movement of beds as a part of the evacuation process. 

Where bed evacuation is likely, the corridors including junctions and turning spaces must be designed in order that both the bed and the staff members involved in moving the bed can negotiate the space easily. This involves the corridors being of sufficient width to do so. Specific guidance on corridor widths including handrails and doorways is provided in Health Building Note 00-04 – ‘Circulation and communication spaces’. 

Potential alternatives to the guidance given are possible if evidence is provided by an architect and approved by the client, building control officer and fire officer.  Additionally, alternative methods of evacuation may be possible where it can be shown that the proposed plan recognises the limited mobility of the patients and provides a design solution enabling staff to safely manage the evacuation.

In cases where communal bathrooms are provided, these must be classed as fire hazard rooms.

In part 12 of this series, LWF will look at the effective separation of areas accessed by patients from other parts of the premises. In the meantime, if you have any queries about fire safety in healthcare premises or wish to discuss this blog series, please contact Peter Gyere in the first instance on 0208 668 8663.

Lawrence Webster Forrest is a fire engineering consultancy based in Surrey with over 25 years' experience, which provides a wide range of consultancy services to professionals involved in the design, development and construction and operation of buildings. 

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.


Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Firefighting & The Fire Service - Part 18

    In LWF's Fire Engineering blog series for Architects and others involved in building design, we have been looking at firefighting. In part 17, we began to look at how firefighting is undertaken by the Fire Service and their objectives and modes of operation when arriving at a fire. In part 19, tactical firefighting is discussed.While the general objectives of tactical firefighting were given in the last blog, there are various methods used by firefighters...

    Read more...

  • Fire Safety for Healthcare Premises - Open-sided Car Parks - Part 52

    In LWFs blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 51 of this series, we were looking at the potential for fire spread from one area of a building to another through external surfaces, before moving on to begin to look at the necessary arrangements for car parks. In part 52, we continue on that theme by considering...

    Read more...

  • Facilities Management & Fire Safety - Calculating RSET - Part 9

    In LWFs blog series for those who work in Facilities Management or who have an interest in or responsibility for fire safety we have been looking at fire safety engineering. In part 8, we looked at how ASET (Available Safe Egress Time) is calculated and how this should always be more than the RSET (Required Safe Egress Time). While ASET involves a series of calculations relating to fire growth and the building itself, RSET, also...

    Read more...

  • Fire Engineering Design and Risk Assessment - Firefighting & The Fire Service - Part 17

    In LWF’s fire engineering blog series for Architects and others in the business of building design, we have been looking at firefighting. In part 16, we discussed first-aid firefighting by the occupancy and the use of hose reels to do so. In part 17, we will begin to look at firefighting from the point of view of the Fire Services.The particular objectives of the Fire Service in a given situation will be decided upon...

    Read more...

  • Fire Safety for Healthcare Premises - External Fire Spread - Part 51

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 50 of this series, we discussed the potential for external fire spread including calculating unprotected areas and consideration of the surfaces of external walls and roofs. In part 51, we continue looking at external fire spread, starting with junctions of different elements.At the junction of wall and...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London