Fire Safety for Healthcare Premises - Hospital Streets & Vertical Escape - Part 4

Posted by LWF: 11/01/2018 14:25

Fire Safety for Healthcare premises is a blog series by LWF, aiming to give guidance on healthcare-based standards and best practice in fire safety. Part 3 looked Progressive Horizontal Evacuation – the movement of patients from an area affected by fire to an adjacent fire protected area. Part 4 gives an overview of Hospital Streets, what they are designed to do and how they are used, before moving on to look at Vertical Escape.

A Hospital Street links together the hospital departments, stairways and lifts and is the route used by staff, patients and visitors to move about the premises between areas. While they are commonly seen in large healthcare premises, they are not a requirement in small hospitals and other healthcare premises.

In terms of fire safety, a Hospital Street is a protected compartment that connects with all the department entrances, final exits from the building and methods of moving between floors (lifts/stairways). As it is a separate fire-protected compartment from each area leading from it (such as a hospital department), if a fire develops in an area off the corridor, the occupants of that area can be safely evacuated via the Hospital Street to a safe adjacent area.

Hospital Street is also the place that the Fire Service would assemble and organise their fire-fighting activities as it is a safe area from which to operate.
While Part 3 of this series looked at Progressive Horizontal Evacuation, the movement of patients from an area affected by fire to an adjacent protected area, in severe fire situations, it may be necessary to begin moving staff and patients from that floor of the building to a floor closer to the final exit. This vertical movement of the evacuation process should only occur when the growth of a fire threatens the safety of occupants outside the compartment of fire origin, as there are additional risks to patients and staff during vertical escape.

In some buildings, accommodation stairs are designated separate from fire escape stairs, but in the case of a hospital, this is inappropriate. All stairways should be potential escape stairs, as they must all be able to be used in a fire emergency. The only exception to this is stairs which are wholly contained within an atrium and only serve the atrium.

While the use of lifts to achieve vertical evacuation can be most beneficial in order to safely evacuate dependent and high dependency patients, the subject will be further discussed later in this series, as lifts which can be used during a fire situation must be subject to certain building regulations.

In Part 5 of this series, we will look at the different classifications of patients according to Firecode. In the meantime, if you have any queries about fire safety in healthcare premises or wish to discuss this blog series, please contact Peter Gyere in the first instance on 0208 668 8663.

Lawrence Webster Forrest is a fire engineering consultancy based in Surrey with over 25 years' experience, which provides a wide range of consultancy services to professionals involved in the design, development and construction and operation of buildings. 

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Planning Sprinkler Installations - Part 29

    In LWF’s Fire Engineering and Risk Assessment blog series for Architects and others in the building design industry, we have been reviewing the proper planning of sprinkler protection as a part of the design process. In Part 28, the necessity for consultation with all relevant parties was discussed and in Part 29, we examine the building itself and how that will impact upon sprinkler installation.It is important to ascertain the nature of the proposed...

    Read more...

  • Fire Safety for Healthcare Premises - Types of Patient Dependency - Part 5

    Fire Safety for Healthcare premises is a blog series by LWF, aiming to give guidance on healthcare-based standards and best practice in fire safety. In Part 4, the use of vertical escape practices after horizontal escape had already been completed was discussed. In Part 5, we’ll look at how Firecode classifies patient dependency for the purposes of successful evacuation.Firecode separates patient dependency into three distinct classifications, as follows:Independent – An...

    Read more...

  • Facilities Management & Fire Safety - How people act in a fire situation - Part 1

    In LWF’s blog series for those who work in Facilities Management or who have a responsibility for or interest in fire safety, we have been exploring those areas of fire prevention and protection which are of prime concern to building owners and managers in a structural and practical manner. We now turn our attention to the variable element of any fire situation – people.While the majority of guidance on fire safety relates to the...

    Read more...

  • Fire Safety for Healthcare Premises - Hospital Streets & Vertical Escape - Part 4

    Fire Safety for Healthcare premises is a blog series by LWF, aiming to give guidance on healthcare-based standards and best practice in fire safety. Part 3 looked Progressive Horizontal Evacuation – the movement of patients from an area affected by fire to an adjacent fire protected area. Part 4 gives an overview of Hospital Streets, what they are designed to do and how they are used, before moving on to look at Vertical Escape.A...

    Read more...

  • Fire Engineering Design and Risk Assessment - Planning Sprinkler Installations - Part 28

    In LWF’s Fire Engineering and Fire Safety blog series for Architects and others involved in building design, we have been looking at the many options of sprinkler installation available and how they work within the constraints of the building. In Part 28, we will discuss planning for a sprinkler installation.When preparing for the installation of a sprinkler system, proper planning will ensure that the following essential criteria are met:- The sprinkler system...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London