Fire Engineering Design and Risk Assessment - Sprinkler Design Codes - Part 12

Posted by LWF: 13/09/2017 12:24

In this Fire Engineering Design and Risk Assessment blog series by LWF for Architects and others in the building design business, we have been discussing sprinklers and the design codes affecting installation and use. In Part 11, it was noted that there may be areas of a building in which sprinklers are not advisable but that in these cases, suitable alternative protection must be provided. 

With that in mind, most design codes lay out the need for protection throughout a building, as well as any connected buildings and any neighbouring sites which are in close proximity. Where connecting or closely positioned buildings are not suitably protected, it will be necessary to further protect the original structure from the additional risk of the unprotected building.

While this additional protection is usually provided in a structural manner, it is not uncommon to see drencher systems used externally to make sure that fire cannot pass between the two buildings.

While codes give prescriptive solutions to such problems, a fire engineered approach will differ in that it approaches the situation through assessment of circumstances such as fire load, the level of fire-resistant construction and the risk of fire spreading. Through this method, it is possible to pinpoint the risk areas and use sprinklers for protection.

Where buildings are to have areas which are sprinklered and those which are not, it is important that suitable compartmentation is implemented between those areas, or indeed that areas without fire load are used to provide virtual compartmentation. One such example would be railway platforms.

When considering the protection of a building, it may be that there are areas which would not be safe if sprinklers were to be in use, such as working areas where metal would be melted or in some kitchen environments. In these cases, it is essential that the risk of the non-sprinklered area is mitigated and a suitable solution chosen to ‘fill the gap’. It may be that a gaseous or water mist system is required, or, depending upon circumstances, separation by fire-resisting construction may be sufficient.

Of course, while each unsprinklered area must be considered fully, there may be areas of the building where sprinklers are not required due to a lack of fire load. Most commonly, these might be toilets, lifts and stairways. In each case, fire-resistant construction should be employed to avoid the fire spreading through these unprotected areas.

In the area between the protected (sprinklered) area and the non-protected area, there may be a need to install cut off sprinklers. These units are positioned above windows, doorways or other potential apertures on the unprotected side to improve fire-resistance and separation.

In part 13 of this series, we will look at the hazard classifications of risks which enable them to be suitably matched with sprinkler systems. In the meantime, if you have any questions about this blog, or wish to discuss your own project with one of our fire engineers, please contact us.

Lawrence Webster Forrest has been working with their clients for over 25 years to produce innovative and exciting building projects. If you would like further information on how LWF and fire strategies could assist you, please contact Peter Gyere on 020 8668 8663.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Foam System Discharge Devices continued - Part 7

    In LWF’s fire engineering blog series for architects and others in the building design industry, we have been discussing methods of fire suppression. In part 6, some of the types of foam system discharge devices were outlined and in part 7, that is continued before moving on to look at Foam system designs.A foam inlet system involves a breeching on the outside of a building being used by the Fire Service to pump foam...

    Read more...

  • Fire Safety for Healthcare Premises - Intensive Care Protection - Part 26

    In LWF’s blog series for healthcare professionals, we look to give information on best practice in fire safety for hospitals and other healthcare premises. In part 25, the use of external escape routes was raised and an outline given of how to give a safe and viable outside route to an external assembly point.  In part 26, LWF looks at the protection of those patients in Intensive Care wards in case of fire.The avoidance...

    Read more...

  • Facilities Management & Fire Safety - Inspection, Testing and Maintenance - Part 4

    In LWF’s blog series for people who work in Facilities Management or those with an interest in or responsibility for fire safety, we have been looking at the inspection, testing and maintenance regimen required in an organisation and how it should be carried out by the responsible person or relevant sub-contractor or in-house qualified personnel. In part 3, the checks that must be carried out on a daily, weekly, monthly and quarterly basis were outlined....

    Read more...

  • Fire Safety for Healthcare Premises - External Escape Routes - Part 25

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 24 of this series, the fire safety requirements for final exits was outlined and in part 25, we look at external escape routes.While the escape routes from any point inside a building to the outside are extremely important, it is also important to look at the route...

    Read more...

  • Fire Engineering Design and Risk Assessment - Foam System Discharge Devices - Part 6

    In LWF’s fire engineering blog series for Architects and others in the building design business, we have been looking at methods of fire suppression. In part 5, the different types of foam system were outlined and in part 6, we take a look at what is available in terms of foam system discharge devices.Foam ChambersUsed as a part of cone roof storage tanks, a foam chamber contains a vapour seal, the role of...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London