Fire Engineering Design and Risk Assessment - Gaseous Systems - Part 9

Posted by LWF: 28/06/2018 13:13

In LWF’s fire engineering blog series for architects and others in the building design industry, we have been looking at methods of fire suppression. In part 8, we finished looking at Foam Systems. In part 9, we will discuss the types and uses of Gaseous Systems.

Gaseous systems are those fire-fighting active protection systems whereby the agent used to extinguish fire is applied in a gas form. Gaseous systems can be used to protect areas with electrical risks, such as communications equipment, server rooms and Electronic Data Processing (EDP) Facilities. They can also be found useful in Class A hazard areas which would include hazards from paper, wood, plastic and Class B hazards, like flammable liquid fires.

In the past, halon was a popular gaseous agent, but as its use is now strictly limited to a very few circumstances, such as the Channel Tunnel, substitutes were found in agents from one of two classes – halocarbon or inert.

Halocarbon gases act to absorb heat, but also may have some chemical effect on the flame combustion reactions. Inert agents are designed to reduce the oxygen to below the level at which fires can continue to combust.

Gaseous systems can be classed as having the following objectives:

- To extinguish a fire
- To limit the spread of a fire
- To limit the damage caused by fire
- To prevent re-ignition of a fire previously extinguished
- To enable day to day operations to continue in short order

There are some secondary benefits to the use of gaseous systems when compared to other forms of fire suppression, namely that there is a limited amount of smoke produced and as they are ‘clean agents’ there will be no additional post-fire clean-up necessary due to the method of agent application.

Some reference documents in the UK and abroad for gaseous systems are as follows:

BS EN 15004-1:2008 - Fixed firefighting systems. Gas extinguishing systems. Design, installation and maintenance 

BS 5306-4:2001+A1:2012 - Fire extinguishing installations and equipment on premises. Specification for carbon dioxide systems

NFPA 2001 - Standard on Clean Agent Fire Extinguishing Systems

Aside from the first two documents being produced as British Standards for European use and the third by the NFPA in the US, a further difference is that the BS EN standard requires higher Class A concentrations than the NFPA reference, due to increased safety margins and different test methods.

In part 10 of this series, LWF will look at system configurations for gaseous systems. In the meantime, if you have any questions about this blog, or wish to discuss your own project with one of our fire engineers, please contact us.

Lawrence Webster Forrest has been working with their clients for over 25 years to produce innovative and exciting building projects. If you would like further information on how LWF and fire strategies could assist you, please contact Peter Gyere on 020 8668 8663.

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Halocarbon Agents - Part 12

    In LWF’s fire engineering blog series for architects and others in the building design business, we have been looking at Fire Suppression and most recently, gaseous systems. In part 11, we looked at the effect of gases on the environment and in part 12, we’ll discuss halocarbon agents and inert agents before touching on water mist systems.Halocarbon agentsHalocarbon agents were developed as a viable alternative to halons after the substance was banned for...

    Read more...

  • Fire Safety for Healthcare Premises - Thermoplastic Materials - Part 31

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 30, we discussed the potential for internal fire spread and in part 31, we take a look at the use of thermoplastic materials in roof lights and lighting diffusers.In part 30, the national and European classifications for linings within spaces contained in healthcare buildings were detailed. The...

    Read more...

  • Facilities Management & Fire Safety - Taking action upon finding a fire - Part 5

    In LWF’s blog series for those who work in Facilities Management, or who have an interest in or responsibility for fire safety, we have been looking at fire procedures; who they are written for and how they should be written.  Parts 3 and 4 of this series looked at summoning the fire service to a fire and in part 5, we look at what other action should be taken upon fire discovery.The issue of...

    Read more...

  • Fire Safety for Healthcare Premises - Internal Fire Spread - Part 30

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 29 of this series, we looked at plant areas and how they should be designed with safe evacuation in mind. In part 30, we discuss the potential for fire to spread through internal walls and how this...

    Read more...

  • Fire Engineering Design and Risk Assessment - Agents used in Gaseous Systems - Part 11

    In LWF’s Fire Engineering and Risk Assessment blog series for architects and others in the building design business, we have been looking at gaseous systems as a method of fire suppression. In part 10 of this series, the required configuration of gaseous systems was outlined and in part 11, the agents used in such systems will be discussed from the point of view of safety and the environment.After the banning of halon 1301 for...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London