Fire Engineering Design and Risk Assessment - Gaseous Systems - Part 9

Posted by LWF: 28/06/2018 13:13

In LWF’s fire engineering blog series for architects and others in the building design industry, we have been looking at methods of fire suppression. In part 8, we finished looking at Foam Systems. In part 9, we will discuss the types and uses of Gaseous Systems.

Gaseous systems are those fire-fighting active protection systems whereby the agent used to extinguish fire is applied in a gas form. Gaseous systems can be used to protect areas with electrical risks, such as communications equipment, server rooms and Electronic Data Processing (EDP) Facilities. They can also be found useful in Class A hazard areas which would include hazards from paper, wood, plastic and Class B hazards, like flammable liquid fires.

In the past, halon was a popular gaseous agent, but as its use is now strictly limited to a very few circumstances, such as the Channel Tunnel, substitutes were found in agents from one of two classes – halocarbon or inert.

Halocarbon gases act to absorb heat, but also may have some chemical effect on the flame combustion reactions. Inert agents are designed to reduce the oxygen to below the level at which fires can continue to combust.

Gaseous systems can be classed as having the following objectives:

- To extinguish a fire
- To limit the spread of a fire
- To limit the damage caused by fire
- To prevent re-ignition of a fire previously extinguished
- To enable day to day operations to continue in short order

There are some secondary benefits to the use of gaseous systems when compared to other forms of fire suppression, namely that there is a limited amount of smoke produced and as they are ‘clean agents’ there will be no additional post-fire clean-up necessary due to the method of agent application.

Some reference documents in the UK and abroad for gaseous systems are as follows:

BS EN 15004-1:2008 - Fixed firefighting systems. Gas extinguishing systems. Design, installation and maintenance 

BS 5306-4:2001+A1:2012 - Fire extinguishing installations and equipment on premises. Specification for carbon dioxide systems

NFPA 2001 - Standard on Clean Agent Fire Extinguishing Systems

Aside from the first two documents being produced as British Standards for European use and the third by the NFPA in the US, a further difference is that the BS EN standard requires higher Class A concentrations than the NFPA reference, due to increased safety margins and different test methods.

In part 10 of this series, LWF will look at system configurations for gaseous systems. In the meantime, if you have any questions about this blog, or wish to discuss your own project with one of our fire engineers, please contact us.

Lawrence Webster Forrest has been working with their clients for over 25 years to produce innovative and exciting building projects. If you would like further information on how LWF and fire strategies could assist you, please contact Peter Gyere on 020 8668 8663.

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Compartmentation & Life Safety - Part 5

    In LWF’s Fire Engineering blog series for Architects and others working in the building design business, we have been discussing compartmentation. In part 4 of this series, the ways in which compartmentation supports life safety functions in a fire situation were summarised. In part 5, we look at the ways the issue of compartmentation and life safety is covered in the national building regulations, before looking at the spread of fire. 

    Read more...

  • Fire Safety for Healthcare Premises - Compartmentation & Fire Hazard Rooms and Areas - Part 39

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 38 of this series, the importance of fire stopping the joints between fire separating elements such as walls and any openings was discussed. In part 39, we will continue in that area by looking at fire hazard rooms and areas.While most types of buildings require the protection...

    Read more...

  • Facilities Management & Fire Safety - Content of Fire Training - Part 13

    In LWF’s blog series for those who work in Facilities Management, or who have an interest in or responsibility for Fire Safety, we have been looking at the necessity for staff training and fire drills. In part 12 we looked at the implications of committing to fire safety training in a business or organisation in terms of time commitment. In part 13, the necessary content of the fire safety training sessions is outlined. All comprehensive...

    Read more...

  • Fire Engineering Design and Risk Assessment - Maintenance of Compartmentation - Part 4

    In LWF’s Fire Engineering blogs for Architects and others who work in the building design business, we have been looking at compartmentation of buildings to avoid fire spread from the compartment of fire origin to any other area. In part 3 of this series, the fire-resisting performance of elements which go into comprising a fire-resistant compartment was discussed. In part 4, we discuss how a compartment’s integrity is only as good as its ongoing maintenance,...

    Read more...

  • Facilities Management & Fire Safety - Staff Training & Fire Drills - Part 12

    In LWF’s blog series for those who work in Facilities Management, or who have an interest in or responsibility for fire safety, we have been looking at staff training and fire drills. In part 11 of this series, methods of training were discussed and in part 12, we will continue from that point to discuss the practicalities of who should receive training and how it should be organised.Adequate fire training should be given to...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London