In LWF’s Fire Engineering blog series for Architects and others in the building design business, we have been looking at methods of fire suppression. In part 1, we looked at the suitability of foam systems for distinct kinds of potential fires. In part 2, we give an overview of the various types of foam typically available.

Each type of foam concentrate can be performance classified with three properties in mind. These are speed, heat resistance and fuel pick-up. 

Protein foam has poor speed, poor fuel pick-up and excellent heat resistance. It is normally made with hydrolysed protein (animal protein concentrate) and produces a stiff foam which must be aspirated before use. Overall, it has poor firefighting properties.

Fluoroprotein foam exhibits fair speed response to fire, excellent heat resistance and good fuel pick-up (good fuel pick-up indicates low fuel pick-up). Just like standard protein foam, the fluoroprotein foam must be aspirated before use. It is a protein foam made with fluorochemical additives which flows easily.

Film-forming Fluoroprotein foam has a good standard in speed, heat resistance and fuel pick-up. While it can be used at its most effective when aspirated, it can also be used un-aspirated on spill fires. 

Aqueous film-forming foam has excellent speed, fair heat resistance and good fuel pick-up. It is a synthetic foam made with fluorochemical surfactants. As the word aqueous indicates, it is designed to release an aqueous film which flows ahead of the foam giving the excellent speed indicated. The advantage of speed is slightly offset by the inability to produce a durable foam blanket effect. It can be used effectively in both aspirated and unaspirated forms and delivered through any water delivery nozzle, including through sprinklers.

Alcohol-resistant foam is able to produce good speed, excellent heat resistance and good fuel pick-up. They are used on fires involving foam-destructive flammable liquids which absorb water, such as alcohols and methanol. The film produced is polymeric which protects the water in the foam bubbles. The majority of available foams have an AR version. AR foams have a much higher viscosity than normal foams and so care must be taken by designers when considering proportioner performance. 

In part 3 of this series, LWF will continue the overview of available foams for firefighting with Synthetic/high-expansion foams, Class A foam and Fluorine-free foams before looking at foam proportioning. In the meantime, if you have any questions about this blog, or wish to discuss your own project with one of our fire engineers, please contact us.

Lawrence Webster Forrest has been working with their clients for over 25 years to produce innovative and exciting building projects. If you would like further information on how LWF and fire strategies could assist you, please contact Peter Gyere on 020 8668 8663.

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Firefighting & External Water Supplies - Part 22

    In LWFs fire engineering blog series for Architects and others involved in building design, we have been looking at the subject of firefighting. In part 21, the issue of whether a building needs to supply a source of water for the Fire Service to use upon attending a fire was discussed. In part 22, we continue looking at the regulations dealing with water hydrants.In the UK, BS 5306:1 was published in 1976 (and withdrawn...

    Read more...

  • Fire Safety for Healthcare Premises - Access & Facilities for the Fire Service - Part 56

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 55 of this series, we began looking at the importance of access by road for the Fire Service and which entrances should be used for their access. In part 56, LWF will continue looking at those measures which should be taken to ensure the Fire Service has access...

    Read more...

  • Facilities Management & Fire Safety - Fire Safety Objectives - Part 3

    In LWFs blog series for those who work in Facilities Management, or who have an interest in or responsibility for fire safety, we have been looking at property protection and the insurer. In part 2, it was ascertained that while there is a legal requirement for buildings to be fire safe in order to ensure the safe evacuation of the building occupants, there is no legal requirement for precautions which are designed for the protection...

    Read more...

  • Fire Engineering Design and Risk Assessment - Firefighting & External Water Supplies - Part 21

    In LWF’s fire engineering blog series for Architects and others involved in building design we have been looking at firefighting. In part 20, an outline of how the water carried by a fire engine is used with the hoses to provide a limited time supply of water to fight a fire. In part 21, we continue from that point.As a fire engine can only carry a limited amount of water, a large fire will...

    Read more...

  • Fire Safety for Healthcare Premises - Access & Facilities for the Fire Service - Part 55

    In LWFs blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 54 of this series, we finished our discussion on ventilation for car parks as part of healthcare buildings. In part 55, we move on to look at the provision of access and facilities for the Fire Service both in terms of general requirements and those particular to healthcare...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London