Fire Engineering Design and Risk Assessment - Firefighting Shafts - Part 46

Posted by LWF: 17/06/2019 14:07

In LWF’s recent Fire Engineering blog series for Architects and others in the building design industry, we have been looking at Firefighting. In part 45, we looked at recommendations for the provision of firefighting shafts contained in Approved Document B and BS 9999. In part 46, we consider what those documents have to say on general design considerations for firefighting shafts.

Approved Document B and BS 9999 both contain information in relation to the provision and design of firefighting shafts in buildings and coincide with their recommendations overall. While an overview of the general standards can be helpful, the source documents should be read for design detail.

A firefighting shaft might consist of lobbies and a staircase within a protected enclosure and/or a firefighting lift. The shaft should serve every storey it passes through and be located in the building so that every part of every storey is no more than 60 m travel distance from the fire main outlet. 

Only those services which are required for the firefighting shaft should be contained within the protected enclosure of the shaft and none may pass through. The shaft should not contain any cupboards or access to service shafts servicing the remainder of the building.

Firefighting lobbies and stairs contained within the shaft must have facilities for smoke control and have emergency lighting fitted and operational.

The lobbies in a firefighting shaft must have a clear floor area of not less than 5 m2. The floor area should not exceed 20 m2 for lobbies serving up to four lifts, and the basis for expanding on that for lobbies containing more than four lifts should be 5 m2 per lift. Principal dimensions should be not less than 1.5 m and should not exceed 8 m in lobbies serving up to four lifts, or 2 m per lift in those lobbies which serve more than four lifts. Lobbies are restricted in size to reduce the likelihood of inappropriate use, for ad-hoc storage for example.

In blocks of flats, or buildings containing flats, protected ventilated common corridors or lobbies are expected to protect the firefighting stairs without the need to provide additional dedicated ventilated lobbies. In circumstances where a firefighting shaft is pressurised, however, a lobby should be provided.

Entrance to a firefighting shaft at Fire Service access level (usually ground) should be available either from the open air or by way of a protected corridor not exceeding 18 m in length, reducing the distance firefighters have to travel. In circumstances where a corridor is required as part of the design, the corridor should be considered a part of the firefighting shaft and any access to the corridor from the accommodation should be by way of protected lobbies.

In part 47 of this series, LWF will continue to look at the general design considerations in Approved Document B and BS 9999 for firefighting shafts. In the meantime, if you have any questions about this blog, or wish to discuss your own project with one of our fire engineers, please contact us. 

Lawrence Webster Forrest has been working with their clients for over 25 years to produce innovative and exciting building projects. If you would like further information on how LWF and fire strategies could assist you, please contact Peter Gyere on 0800 410 1130.

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Safety for Healthcare Premises - Fire Safety Training for Staff - Part 84

    In LWFs blog series for healthcare professionals, our aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 83, LWF began look at those roles in a healthcare environment which might have special responsibilities in case of a fire and while it is not possible to provide an exhaustive list which applies to all, those staff who will be expected to assist in patient evacuation were...

    Read more...

  • Fire Safety for Facilities Management Personnel - Fire Safety Legislation - Part 2

    Lawrence Webster Forrest (LWF) is a specialist fire engineering and fire risk management consultancy whose aim is to give information on best practice in fire safety for facilities management personnel through this blog series. In part 1, we began an overview of the history of fire safety legislation, which we continue in part 2.In the last blog, it was ascertained that following a fire disaster, it is common to see changes in legislation with...

    Read more...

  • Fire Engineering Design and Risk Assessment - Provision of Firefighting Shafts - Part 50

    In LWF’s Fire Engineering blog series for Architects and others in the building design business, we have been discussing firefighting and what provisions must be made for firefighting activities in a building. In part 49, we examined some of the criteria given in different guidance documents and in particular, how it is recommended that a firefighting lobby should be used as access to the accommodation from a firefighting lift or stair as a single fire...

    Read more...

  • Fire Safety for Healthcare Premises - Fire Safety Training for Staff - Part 83

    In LWFs blog series for healthcare professionals, our aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 82, LWF looked at what elements make up an effective fire safety training policy. In part 83, we begin by discussing the use of e-learning as a tool in fire safety training, before looking at training for staff with special responsibilities.E-learning, or learning which is undertaken on...

    Read more...

  • Fire Safety for Facilities Management Personnel - Fire Safety Legislation - Part 1

    Lawrence Webster Forrest (LWF) is a specialist fire engineering and fire risk management consultancy whose aim is to give information on best practice of fire safety for facilities management personnel through this blog series. In part 1, we begin with an overview of the history of fire safety legislation.While it is true that most fire safety legislation is written with the aim of averting fires, it is also the case that much of it...

    Read more...

Case Studies

Brentwood Town Hall Redevelopment
The redevelopment of Brentwood Town Hall included renovating the existing five storey property to provide police and council offices, a community hub and lettable office space across the basement, gro...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development Croydon