Fire Engineering Design and Risk Assessment - Firefighting & External Water Supplies - Part 22

Posted by LWF: 10/01/2019 12:48

In LWFs fire engineering blog series for Architects and others involved in building design, we have been looking at the subject of firefighting. In part 21, the issue of whether a building needs to supply a source of water for the Fire Service to use upon attending a fire was discussed. In part 22, we continue looking at the regulations dealing with water hydrants.

In the UK, BS 5306:1 was published in 1976 (and withdrawn and updated in 2006, replaced by BS 5306:1-2006 and BS 9990:2006 and dealt with water hydrant systems. It recommended that fire hydrants are installed on a ring fire main system and are positioned not more than 70 metres from an entry point of any building on site and not more than 150 metres apart from each other. They should be no closer than 6 metres to the building.

In 2002, following a study, the Local Government Association and Water UK produced a document titled ‘National guidance document on the provision of water for fire fighting’ (PDF) which linked flow rates of water in litres per second to differing structures. It showed that there were significant variations in flow rate even within the same structure groups. It went on to say that if the water supply is not in the control of the building owner (e.g. an owned lake) it is only the water undertaking which can vary the flow from a main.

Another source from the UK – Approved Document B in subsection 15.7 states:

‘Where a building, which has a compartment of 280 m2 in area, is being erected more than 100 metres from an existing fire hydrant, additional hydrants should be provided as follows:

(a) Buildings provided with fire mains - hydrants should be provided within 90 m of dry fire main inlets.

(b) Buildings not provided with fire mains - hydrants should be provided within 90 m of an entry point to the building and not more than 90 m apart.

The implication is that the building owner should arrange and pay for the hydrants as indicated, although it must, once again, be noted that there is no legal requirement for a building owner to provide water sources for fire-fighting by the Fire Service.

LWF’s discussion about issues surrounding fire hydrants and the provision of them will continue in part 23 of this series. In the meantime, if you have any questions about this blog, or wish to discuss your own project with one of our fire engineers, please contact us. 

Lawrence Webster Forrest has been working with their clients for over 25 years to produce innovative and exciting building projects. If you would like further information on how LWF and fire strategies could assist you, please contact Peter Gyere on 020 8668 8663.

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Firefighting & External Water Supplies - Part 33

    In LWF’s Fire Engineering blog series for Architects and others in the building design business, we have been looking at firefighting and the associated provisions that need to be made for the Fire Service. In part 32, we looked at the standards for wet and dry mains given in Approved Document B and BS 9999. In part 33, we consider dry mains in more detail.A dry rising main is comprised of pipework installed vertically...

    Read more...

  • Fire Safety for Healthcare Premises - Fire Safety Policies - Part 67

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 66, we were discussing how fire safety policies should be formed and finished by noting that consultation with all types and levels of staff in a healthcare setting is necessary to ensure a considered and cohesive fire safety policy. In part 67, LWF will continue looking at fire...

    Read more...

  • Facilities Management & Fire Safety - Insurers & Property Protection - Part 14

    LWF’s blog series for those who work in Facilities Management, or who have an interest in or responsibility for fire safety has been looking at the impact of the insurer on property protection from fire. In part 13, while acknowledging there are significant areas of overlap between life safety and property protection measures, we began to look at those areas where measures taken to protect property from fire would not benefit life safety aims, and...

    Read more...

  • Fire Engineering Design and Risk Assessment - Firefighting & Internal Water Supplies - Part 32

    In LWF’s Fire Engineering blog series for Architects and others involved in the building design business, we have been looking at fire safety engineering and, most recently, firefighting. In part 31, we looked at the recommendations made regarding water capacity for any open water used for firefighting purposes and discussed relaying water to the place of fire origin. In part 32, we look at internal water supplies designed for the purpose of firefighting.Fire mains...

    Read more...

  • Fire Safety for Healthcare Premises - Fire Safety Policies - Part 66

    In LWF’s blog series for healthcare professionals, our aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 65, LWF considered some of the many important elements when considering general fire safety in a healthcare building, including the provision of alternative escape routes and the potentially unpredictable nature of human behaviour in a fire situation. In part 66, we look at fire safety policies.Clearly-defined fire...

    Read more...

Case Studies

Duke of York, Victoria Street, London
The Duke of York is a busy pub in central London, used by commuters and theatre-goers alike.  In 2013, the pub was demolished in order to facilitate the London Underground Victoria Station Upgrad...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development Croydon