Fire Engineering Design and Risk Assessment - Firefighting & External Water Supplies - Part 21

Posted by LWF: 03/01/2019 12:40

In LWF’s fire engineering blog series for Architects and others involved in building design we have been looking at firefighting. In part 20, an outline of how the water carried by a fire engine is used with the hoses to provide a limited time supply of water to fight a fire. In part 21, we continue from that point.

As a fire engine can only carry a limited amount of water, a large fire will almost certainly require more water than one engine can deliver. This means that more fire engines may have to be called to the scene, or, in some cases, the fire could be fought successfully by one firefighting team, if access to a hydrant is available. 

Approved Document B now requires private hydrants to be installed to new developments if the building has a compartment larger than 280m2 and is erected more than 100 m from an existing water hydrant. 

If additional water supplies are to be provided, they should be sufficient to provide water for firefighting in offensive mode. 

Fire hydrants are highly effective sources of additional water for the Fire Service, because they are fitted directly to the water mains. There are various national and international standards relating to fire hydrants and water mains, mostly produced by the National Fire Protection Association, based in the US.

NFPA 1: Fire Prevention Code (current edition 2018)  looks at water supply in section 7-5 and refers only to private fire service mains with recommendations that they be installed in accordance with NFPA 24 Standard for the Installation of Private Fire Service Mains and Their Appurtenances.

NFPA 5000: Building Construction and Safety Code (2018) sections 55.8 relating to fire hydrants and 55.9, private fire service mains, both refer to NFPA 24, linked above.

NFPA 24 states the following in relation to the provision of fire hydrants ‘they shall be spaced in accordance with the authority having jurisdiction’ and ‘for average conditions hydrants shall be placed at least 40 feet from the building protected’.

The NFPA Fire Protection Handbook recommends an adequate supply of water at adequate residual pressure as it is the principal agent used to extinguish building fires, in order to fulfil the needs of the fire service and any automatic extinguishing systems. 

In part 22 of this series, LWF will continue to look at fire hydrants, the recommendations and any relevant guidances with British Standards. In the meantime, if you have any questions about this blog, or wish to discuss your own project with one of our fire engineers, please contact us. 

Lawrence Webster Forrest has been working with their clients for over 25 years to produce innovative and exciting building projects. If you would like further information on how LWF and fire strategies could assist you, please contact Peter Gyere on 020 8668 8663.

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.



Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Firefighting & External Water Supplies - Part 33

    In LWF’s Fire Engineering blog series for Architects and others in the building design business, we have been looking at firefighting and the associated provisions that need to be made for the Fire Service. In part 32, we looked at the standards for wet and dry mains given in Approved Document B and BS 9999. In part 33, we consider dry mains in more detail.A dry rising main is comprised of pipework installed vertically...

    Read more...

  • Fire Safety for Healthcare Premises - Fire Safety Policies - Part 67

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 66, we were discussing how fire safety policies should be formed and finished by noting that consultation with all types and levels of staff in a healthcare setting is necessary to ensure a considered and cohesive fire safety policy. In part 67, LWF will continue looking at fire...

    Read more...

  • Facilities Management & Fire Safety - Insurers & Property Protection - Part 14

    LWF’s blog series for those who work in Facilities Management, or who have an interest in or responsibility for fire safety has been looking at the impact of the insurer on property protection from fire. In part 13, while acknowledging there are significant areas of overlap between life safety and property protection measures, we began to look at those areas where measures taken to protect property from fire would not benefit life safety aims, and...

    Read more...

  • Fire Engineering Design and Risk Assessment - Firefighting & Internal Water Supplies - Part 32

    In LWF’s Fire Engineering blog series for Architects and others involved in the building design business, we have been looking at fire safety engineering and, most recently, firefighting. In part 31, we looked at the recommendations made regarding water capacity for any open water used for firefighting purposes and discussed relaying water to the place of fire origin. In part 32, we look at internal water supplies designed for the purpose of firefighting.Fire mains...

    Read more...

  • Fire Safety for Healthcare Premises - Fire Safety Policies - Part 66

    In LWF’s blog series for healthcare professionals, our aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 65, LWF considered some of the many important elements when considering general fire safety in a healthcare building, including the provision of alternative escape routes and the potentially unpredictable nature of human behaviour in a fire situation. In part 66, we look at fire safety policies.Clearly-defined fire...

    Read more...

Case Studies

Duke of York, Victoria Street, London
The Duke of York is a busy pub in central London, used by commuters and theatre-goers alike.  In 2013, the pub was demolished in order to facilitate the London Underground Victoria Station Upgrad...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development Croydon