Facilities Management & Fire Safety - Sprinkler System Heads - Part 11

Posted by LWF: 08/06/2017 11:24

In this blog series for those who work in Facilities Management with an interest in or responsibility for fire safety, we have been looking at the nature and components of a fixed fire-fighting system. In Part 10, we discussed how water supplies for sprinkler systems are classified and graded and what this means for the fire protection level. In Part 11 we’re going to talk about sprinkler heads and how they work in practice.

There are two main types of sprinkler heads, both of which are in general use and are acceptable. The first is Fusible link sprinklers which become operational when heat from a fire melts a soldered link holding the valve closed, thus opening it and allowing water to pass through.

The second is a glass bulb sprinkler head. In this case, heat from a fire causes liquid contained within a glass bulb to heat, expanding the liquid which ultimately breaks the fragile glass and releases the valve to let water pass through.

Positioning of sprinkler heads is dependent upon usage and also aesthetics. Most conventional heads can be mounted as pendent or upright, when the water is discharged, it first hits a plate which deflects it upward and downward to ensure the ceiling is wetted as well as discharging onto the area of the fire. In the case of spray heads, the discharge of water is predominantly downwards.

In some instances, it may be that protruding sprinkler heads are undesirable from an aesthetic point of view or for any other reason. In those cases, it is possible to use flush, recessed or concealed sprinklers. In these circumstances, flush heads are mounted so that a part of the sprinkler head is above the plane of the ceiling, but the heat sensing element remains below the ceiling.

Recessed heads differ in that all or part of the sensing element is above the ceiling too. A concealed sprinkler is in actual fact a recessed sprinkler, but with a cover plate which falls away when the head is exposed to the heat of fire.

While the three types of sprinkler mentioned are useful from an aesthetic point of view, none would be suitable to protect against a high-hazard risk.

Another type of sprinkler which would not be suitable for high-hazard risks is sidewall pattern sprinklers. These sprinklers are mounted in the plane of a wall rather than from a ceiling and throw water outwards when they become operational. The most likely place these will be used would be a corridor or small room, in lieu of ceiling placed heads.

In Part 12, we will continue looking at sprinkler heads and will discuss the effect of temperature on their operation. In the meantime, if you have any queries about your own facilities or wish to discuss this blog series, please contact Peter Gyere in the first instance on 0208 668 8663.

Lawrence Webster Forrest is a fire engineering consultancy based in Surrey with over 25 years' experience, which provides a wide range of consultancy services to professionals involved in the design, development and construction and operation of buildings.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Facilities Management & Fire Safety - Fire & Rescue Service Facilities - Part 5

    In LWF’s blog series for those who work in Facilities Management or who have an interest in or responsibility for fire safety, we have been looking at the facilities required by the Fire and Rescue Service in case of a fire at your premises. As has been established in the previous parts of this series, many of these provisions are physical and should be taken into account when the building is at the design and...

    Read more...

  • Fire Engineering Design and Risk Assessment - Sprinkler System Installations - Part 25

    In LWF’s Fire Engineering blog series for Architects and others in the building design industry, we have been looking at the use of sprinklers as part of active fire protection. In Part 24, the types of sprinkler system were considered, including wet, alternate and dry installations. Part 25 will continue from that point and cover tail-end alternate and tail-end dry systems and pre-action installations.While it is most common for outside temperatures to affect a...

    Read more...

  • Fire Safety for Healthcare Premises - The Basic Principles - Part 1

    Lawrence Webster Forrest (LWF) is a provider of Fire Engineering services and producer of informational resources on the subject of Fire Safety for organisations and companies. Fire Safety for Healthcare premises is a blog series aiming to give guidance on healthcare-based standards and best practice in fire safety and will refer to and draw from sources such as the HTM documents, building regulations, Regulatory Reform (Fire Safety) Order 2005 and other relevant regulations and standards. 

    Read more...

  • Fire Engineering Design and Risk Assessment - Sprinkler System Installations - Part 24

    In LWF’s Fire Engineering blog series for Architects and others in the building design business, we have been looking recently at Sprinkler Systems. In Part 23, we discussed methods of water delivery to the sprinkler heads and ascertained that ‘wet installations’ were the most commonly used type of sprinkler system, meaning that the system is constantly charged with water, ready for operation. In Part 24, we will give an overview of alternate wet and dry...

    Read more...

  • Facilities Management & Fire Safety - Fire & Rescue Service Facilities - Part 4

    In LWF’s blog series for those who work in Facilities Management or who have an interest in or responsibility for Fire Safety, we have recently been discussing the nature of the responsibilities held by a building owner in regard to accessibility for the Fire Service. It was established that along with responsibilities to make relevant information available to the Fire Service and make the property available for familiarisation visits, there are some key elements which...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London