Facilities Management & Fire Safety - Inspection, Testing and Maintenance - Part 3

Posted by LWF: 06/06/2018 12:29

In LWF’s blog series for people who work in Facilities Management, or anyone with an interest in or responsibility for fire safety, we have been looking at the types of inspection, testing and maintenance which must be undertaken to achieve the required standards of fire safety management in an organisation. In part 2, the references and sources which should be taken into consideration when composing the itinerary of checks and tests were outlined, in addition to discussing those relatively simple daily tasks which must be completed. In part 3, we continue from that point to discuss weekly, monthly and quarterly task lists.

On a weekly basis, the following tasks must be completed:

- Checks to escape routes and final exit doors to ensure they are clear of debris, stored items and are fully accessible in case of fire. General housekeeping must also be checked to ensure no fire hazards are developing through an inappropriate storage of goods or rubbish.
- The fire alarm system should be tested as per the manufacturer/installer’s instructions to ensure it continues to function efficiently.
- All door release mechanisms should be checked for correct functionality.
- Sprinkler installations must be inspected, along with any other fire-fighting systems and should be tested.
- Operate the smoke-control systems in place to support safe evacuation from the premises.
- Test the switches provided for both evacuation and fire-fighting lifts.

On a monthly basis, the following must be undertaken:

- Emergency escape lighting should be fully tested, including any battery or generator back-up.
- The visibility and placement of fire safety signs must be checked.
- All provided fire extinguishers must be in place and undamaged, they must be accessible at all times.
- Hose reels should also be checked for damage and still be in place and accessible.
- Generators, vented batteries and any other system to provide back-up power for fire alarm systems should be checked.
- A simulation of loss of main power supply to the evacuation and fire-fighting lifts should be undertaken.

On a quarterly basis, the following checks should be made:

- The sprinkler systems must undergo maintenance to the standard indicated by installer/manufacturer and to align with all relevant guidance.
- All smoke-control systems, including those which are for use by the Fire Service, must be tested and found to work correctly.

In part 4 of this series, LWF will continue the subject of checks, tests and maintenance of fire safety and fire prevention equipment by looking at those checks which must be made on a bi-annual and annual basis. In the meantime, if you have any queries about your own facilities or wish to discuss this blog series, please contact Peter Gyere in the first instance on 0208 668 8663.

Lawrence Webster Forrest is a fire engineering consultancy based in Surrey with over 25 years' experience, which provides a wide range of consultancy services to professionals involved in the design, development and construction and operation of buildings. 

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Compartmentation & Fire Severity - Part 10

    In LWF’s Fire Engineering blog series for Architects and others in the building design industry, we have been looking at the use of compartmentation to avoid the spread of fire. In part 9, the use of compartments with sprinkler systems was discussed and in part 10, we look at the potential severity of fires in enclosed spaces.The severity of a fire in an enclosed space is dependent upon factors such as heat leaving the...

    Read more...

  • Fire Safety for Healthcare Premises - Sprinklers - Part 44

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 43 of this series, we discussed cavity barriers and those areas where they are not practical for use, for fire safety reasons. In part 44, we move on to discuss the use of sprinklers in healthcare buildings. Sprinklers are not a requirement for patient areas of healthcare buildings...

    Read more...

  • Facilities Management & Fire Safety - Fire Safety Engineering - Part 1

    In LWF’s blog series for those who work in Facilities Management or who have an interest in or responsibility for fire safety, we were looking at fire safety training. In Part 1 of this series, however, we begin to review the subject of fire safety engineering. While most people reading on this subject could work out what fire safety engineering is, from the title, LWF will start by looking at the history of fire safety...

    Read more...

  • Fire Engineering Design and Risk Assessment - Compartmentation & Sprinklers - Part 9

    In LWF’s fire engineering blog series for Architects and others in the building design business, we have been looking at compartmentation and how can be used both in prescriptive and fire engineered solutions. In part 8 of this series, the provision of a fire safety strategy for a building was discussed and in part 9, we move onto how compartmentation and sprinklers work together.The effectiveness of sprinkler systems at controlling fires has had a...

    Read more...

  • Fire Safety for Healthcare Premises - Cavity Barriers and Sprinklers - Part 43

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 42 of this series, we looked at how cavity barriers should be installed in uninterrupted concealed spaces or cavities and also some exceptions to the rules. In part 43, we will continue looking at the use of cavity barriers in healthcare buildings.There are some instances where cavity...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London