Posted by LWF: 13/09/2017 12:02

In LWF’s blog series on fire safety for those who work in Facilities Management or who have a responsibility for fire safety in the workplace, we have been looking recently at the use of gaseous systems as a fire protection method. In Part 24, we talked about the different types of gaseous system and how and where they can be used. In Part 25, we’ll discuss the design codes involved before moving on to look at the typical components of such systems.

The majority of types of gaseous system are covered in BS EN 15004-1:2008, Fixed firefighting systems. Gas extinguishing systems. Design, installation and maintenance which covers each of the halocarbon and inert gases in use currently. CO2 systems, however, are dealt with separately in BS 5306-4:2001+A1:2012, Fire extinguishing installations and equipment on premises. Specification for carbon dioxide systems

The components of a typical gaseous extinguishing system can be extensive and so it is essential that suitability for the building is established in every way before proceeding. 

It is necessary to have a facility where the gaseous agent can be stored, as well as an automatic fire detection system which will pinpoint the area in which a fire ignites so that the gas agent can be released. In addition, it is important to have manual release controls in case they are required.

The installation of a gaseous extinguishing system will involve a network of pipes and discharge nozzles in order to deliver the agent at any point throughout the building or area of installation. It is also necessary to have the ability to switch the system between automatic and manual modes and to have a method of total isolation of the system.

The gas storage facility itself will contain a central bank of storage cylinders which are placed outside the protected area of the installation, although in some circumstances it is possible to have the cylinders distributed throughout the protected area.

In the case of a CO2 installation, the gas may be stored in a refrigerated tank and at a lower pressure.

It may be necessary to have a separate and self-contained automatic fire detection system and further guidance on this can be gained from BS 7273-1:2006, Code of practice for the operation of fire protection measures. Electrical actuation of gaseous total flooding extinguishing systems

Particularly in the case of smaller CO2 systems, it may be the case that a simple mechanical means of detection and deployment are all that is necessary. For example, the inclusion of one or more fusible links in the protected area would be attached to a wire under tension. When the heat from a fire melts the fusible link, the wire is released and a weight falls, activating the release mechanism for the gas. 


In Part 26 of this series, we will look at electrically actuated systems and wet chemical systems. In the meantime, if you have any queries about your own facilities or wish to discuss this blog series, please contact Peter Gyere in the first instance on 0208 668 8663.

Lawrence Webster Forrest is a fire engineering consultancy based in Surrey with over 25 years' experience, which provides a wide range of consultancy services to professionals involved in the design, development and construction and operation of buildings.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Safety for Healthcare Premises - In-Patient Mental Health & Learning Disability Facilities continued - Part 9

    In LWF’s blog series for healthcare professionals to give advice and information on best practice of fire safety in hospitals and other healthcare premises. In part 8, we began to give an overview of categories of inpatient mental health services. Part 9 will continue with that breakdown with a view to relating fire safety information to those categories of care.Recovery and rehabilitation services are provided for those adults who have severe and long-term mental...

    Read more...

  • Fire Engineering Design and Risk Assessment - Sprinkler Installation Design - Part 33

    In LWFs Fire Engineering blog series for Architects and others in the building design industry, we have recently been discussing the design and installation of sprinkler systems in new buildings. In part 32, we looked at how sprinklers can work within atriums and where there is a sloping roof or soffit. In part 33, suspended ceilings and pipework systems will be discussed.A suspended ceiling is used to lower the ceiling height of a given...

    Read more...

  • Facilities Management & Fire Safety - How people act in a fire situation - Part 5

    In LWF’s blog series for Facilities Managers and those who have an interest in or responsibility for fire safety, we have been looking at how people react when there is a fire. There has long been a preconception that people panic or act irrationally when informed a fire is in progress, but research has shown this is very rarely the case. In Part 4, the frequency of fire alarm soundings was discussed and in Part...

    Read more...

  • Fire Engineering Design and Risk Assessment - Sprinkler Installation Design - Part 32

    In LWF’s Fire Engineering blog series for Architects and others in the building design business, we have been looking at sprinkler installations and how to approach them. Part 31 went through the basics of the spacing and location of sprinklers in terms of maximum allowable spacing. In Part 32, the location of sprinklers in terms of placement, height and purpose will be explored.Sprinklers should be placed where there are no obstructions to interrupt the...

    Read more...

  • Fire Safety for Healthcare Premises - In-Patient Mental Health & Learning Disability Facilities - Part 8

    Fire Safety for Healthcare premises is a blog series by LWF, aiming to give guidance on healthcare-based standards and best practice in fire safety. In part 7 of this series, we looked at health centres and GP surgeries which may have facilities for minor invasive procedures and how that should impact upon the safety provisions and protocols in place. In part 8, those facilities which provide inpatient mental health care and accommodation for people with...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London