Facilities Management & Fire Safety - Fire & Rescue Service Facilities - Part 8

Posted by LWF: 11/01/2018 14:13

In LWF’s blog series for those who work in Facilities Management or who have an interest in or responsibility for Fire Safety, we have been looking at the facilities which must be provided to the Fire Service, whether structural or in terms of information. In Part 7, smoke control was discussed in terms of initial design and control in case of a fire. In Part 8, we look at what will be needed when the Fire Service arrive at the premises to deal with a fire.

Particularly in the case of large and complex buildings and sites, it is important to prepare a pack for the Fire Service with information on the site. A suitably labelled container should be kept at or near the entrance to the building so that it is accessible to the relevant person who will meet with the Fire Service upon arrival. The information pack should contain all relevant information and plans of each floor, including basements if appropriate; any hazardous materials stored on site; service control locations, sprinkler stop valves and any other information which might be used at the time of a fire.

In addition to the pack, it can be useful for basement plans to be displayed in the building, as well as signs to indicate the whereabouts of potentially hazardous materials. Depending upon the type of hazard, this signage may be legally required in any case.

Communications between Fire Service personnel are of the utmost importance, particularly in large and complex buildings in which their own portable radios may prove unreliable. It is important in such cases that consideration is given to a dedicated communications system for use by the Fire Service in a fire situation. Such systems may involve the placement of dedicated telephones in fire-fighting lobbies as well as a control point at access level. 

BS 5839-9:2011 - Fire detection and fire alarm systems for buildings. Code of practice for the design, installation, commissioning and maintenance of emergency voice communication systems provides the recommendations that should be complied with for the installation of two-way speech communication systems set up for use by the Fire Service. 

As such communication systems are specifically made for use during a fire situation, it is important that they are installed using cables with enhanced fire resistance, to avoid failure when it is most required. BS 8434-2:2003+A2:2009 provides the necessary requirements for that level of fire resistance.

LWF’s next blog for Facilities Management will be ‘Fire and Human Behaviour – Part 1’ as we begin to look at that most unpredictable of variables – people. In the meantime, if you have any queries about your own facilities or wish to discuss this blog series, please contact Peter Gyere in the first instance on 0208 668 8663.

Lawrence Webster Forrest is a fire engineering consultancy based in Surrey with over 25 years' experience, which provides a wide range of consultancy services to professionals involved in the design, development and construction and operation of buildings. 

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Compartmentation & Fire Severity - Part 10

    In LWF’s Fire Engineering blog series for Architects and others in the building design industry, we have been looking at the use of compartmentation to avoid the spread of fire. In part 9, the use of compartments with sprinkler systems was discussed and in part 10, we look at the potential severity of fires in enclosed spaces.The severity of a fire in an enclosed space is dependent upon factors such as heat leaving the...

    Read more...

  • Fire Safety for Healthcare Premises - Sprinklers - Part 44

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 43 of this series, we discussed cavity barriers and those areas where they are not practical for use, for fire safety reasons. In part 44, we move on to discuss the use of sprinklers in healthcare buildings. Sprinklers are not a requirement for patient areas of healthcare buildings...

    Read more...

  • Facilities Management & Fire Safety - Fire Safety Engineering - Part 1

    In LWF’s blog series for those who work in Facilities Management or who have an interest in or responsibility for fire safety, we were looking at fire safety training. In Part 1 of this series, however, we begin to review the subject of fire safety engineering. While most people reading on this subject could work out what fire safety engineering is, from the title, LWF will start by looking at the history of fire safety...

    Read more...

  • Fire Engineering Design and Risk Assessment - Compartmentation & Sprinklers - Part 9

    In LWF’s fire engineering blog series for Architects and others in the building design business, we have been looking at compartmentation and how can be used both in prescriptive and fire engineered solutions. In part 8 of this series, the provision of a fire safety strategy for a building was discussed and in part 9, we move onto how compartmentation and sprinklers work together.The effectiveness of sprinkler systems at controlling fires has had a...

    Read more...

  • Fire Safety for Healthcare Premises - Cavity Barriers and Sprinklers - Part 43

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 42 of this series, we looked at how cavity barriers should be installed in uninterrupted concealed spaces or cavities and also some exceptions to the rules. In part 43, we will continue looking at the use of cavity barriers in healthcare buildings.There are some instances where cavity...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..