Facilities Management & Fire Safety - Fire & Rescue Service Facilities - Part 3

Posted by LWF: 30/11/2017 12:01

In LWF’s blog series for those who work in Facilities Management, or who have an interest in and responsibility for fire safety, we have been looking at the requirements of the Fire Service in relation to facilities provided within a building.

In part 2, we gave an overview of such terms as fire-fighting lift, fire-fighting staircase and talked about how they can be used on a day-to-day basis within the building, only becoming for the use of firefighters when they attend a fire. In Part 3, the recommendations for building specifications will be laid out.

BS 9999:2017 - Fire safety in the design, management and use of buildings - Code of practice provides guidance on the construction and provision of fire-fighting shafts, in support of the building regulations. 

It is recommended that in all buildings over 18m in height, a firefighting shaft is provided which will incorporate a fire-fighting staircase, a fire-fighting lift and a fire-fighting lobby with a rising or falling water main. This recommendation also applies to any buildings which are more than 10m below ground. 

A fire-fighting shaft is also required for any shop, factory or storage building which exceeds 7.5m in height and which incorporates any floor above the ground storey that has an area of 900m2 or more. The shaft itself must contain all the elements named above, with the exception of a fire-fighting lift. This also applies to any building of that area size if there are two or more basement levels.

Buildings which exceed 11m in height will contain one or more storeys than can be reached by the ladders carried on fire appliances. Such buildings should be provided with an escape stair with an unventilated lobby (as per the requirements, it may be ventilated if the design calls for it) and a fire main.

Buildings with a large footprint may need more than one fire-fighting shaft. A shaft should be provided for every 900m2 and the distance between any point in a storey to the door of the nearest fire-fighting shaft should not exceed 60m, measured as the hose would be expected to reach. In a tall (or deep) building, all upper and lower floors should be served by the fire-fighting shaft, although this may be relaxed, dependent upon design, if sprinklers are installed.

In Part 4, we’ll look at the power supply needed to ensure a fire-fighting lift continues to work in a fire situation. In the meantime, if you have any queries about your own facilities or wish to discuss this blog series, please contact Peter Gyere in the first instance on 0208 668 8663.

Lawrence Webster Forrest is a fire engineering consultancy based in Surrey with over 25 years' experience, which provides a wide range of consultancy services to professionals involved in the design, development and construction and operation of buildings. 

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Halocarbon Agents - Part 12

    In LWF’s fire engineering blog series for architects and others in the building design business, we have been looking at Fire Suppression and most recently, gaseous systems. In part 11, we looked at the effect of gases on the environment and in part 12, we’ll discuss halocarbon agents and inert agents before touching on water mist systems.Halocarbon agentsHalocarbon agents were developed as a viable alternative to halons after the substance was banned for...

    Read more...

  • Fire Safety for Healthcare Premises - Thermoplastic Materials - Part 31

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 30, we discussed the potential for internal fire spread and in part 31, we take a look at the use of thermoplastic materials in roof lights and lighting diffusers.In part 30, the national and European classifications for linings within spaces contained in healthcare buildings were detailed. The...

    Read more...

  • Facilities Management & Fire Safety - Taking action upon finding a fire - Part 5

    In LWF’s blog series for those who work in Facilities Management, or who have an interest in or responsibility for fire safety, we have been looking at fire procedures; who they are written for and how they should be written.  Parts 3 and 4 of this series looked at summoning the fire service to a fire and in part 5, we look at what other action should be taken upon fire discovery.The issue of...

    Read more...

  • Fire Safety for Healthcare Premises - Internal Fire Spread - Part 30

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 29 of this series, we looked at plant areas and how they should be designed with safe evacuation in mind. In part 30, we discuss the potential for fire to spread through internal walls and how this...

    Read more...

  • Fire Engineering Design and Risk Assessment - Agents used in Gaseous Systems - Part 11

    In LWF’s Fire Engineering and Risk Assessment blog series for architects and others in the building design business, we have been looking at gaseous systems as a method of fire suppression. In part 10 of this series, the required configuration of gaseous systems was outlined and in part 11, the agents used in such systems will be discussed from the point of view of safety and the environment.After the banning of halon 1301 for...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London