Lawrence Webster Forrest (LWF), Fire Engineering and Fire Risk Management Consultants
Lawrence Webster Forrest (LWF), Fire Engineering and Fire Risk Management Consultants



Navigation

Client login
Forgotten password
Follow us on Twitter Follow us on Facebook Subscribe to our blog

Lawrence Webster Forrest
Legion House
Lower Road
Kenley
Surrey
CR8 5NH

Tel: +44 (0)20 8668 8663 Fax: +44 (0)20 8668 8583
E-mail: fire@lwf.co.uk

Facilities Management & Fire Safety - Content of Fire Training - Part 17

Posted by LWF: 11/10/2018 11:36

In LWF’s blog series for those who work in facilities management or who have an interest in or responsibility for fire safety, we have been looking at what elements should be included in staff fire training. In part 16, we discussed the inclusion of general fire precautions in fire safety training and began to look at fire drills including the legislation that makes them compulsory. In part 17, we will continue from that point.

Despite the necessary nature of fire drills, they are not always taken seriously by employees or management as they often considered an unnecessary interruption to day-to-day business. Fire drills however, can be useful to highlight potential issues, a common issue being that occupants fail to use the nearest fire exit, instead taking the route they are most familiar with and used to following. Such mistakes can increase the evacuation time and be potentially dangerous in a fire situation.

The evacuation time is considered the time taken between the alarm sounding and the last person evacuating the building and this should be noted at each fire drill. Where premises have more than one stairway, the use of one should be prohibited to ensure that all employees are forced to use alternative routes. Fire drills should aim to force employees to utilise various different routes each time to ensure all scenarios are considered. Acceptable evacuation times should still be possible with alternative routes in use.

Each fire drill should be commenced by one employee being asked to operate the manual call point before each and every occupant evacuates the building, including any persons with mobility issues, disabilities and senior management. Exemptions should only be made where it is critical a person remains in the building for the continuous operation of some essential task. Where possible, the same person should not be asked to remain working for two consecutive fire drills. The details of the exemption, the reasons and the person asked to remain inside must be kept.

In a real fire situation, there is never a reason for a person to stay inside the building and no such thing as an essential task that must be run continuously.
After a fire drill has taken place, a debrief must be undertaken to review the outcomes and isolate and solve any potential problems. The results should be minuted at company health and safety meetings.

Next time, LWF’s blog series will begin looking at the subject of Fire Safety Engineering. In the meantime, if you have any questions about this blog, or wish to discuss your own project with one of our fire engineers, please contact us.

Lawrence Webster Forrest has been working with their clients for over 25 years to produce innovative and exciting building projects. If you would like further information on how LWF and fire strategies could assist you, please contact Peter Gyere on 020 8668 8663.

While care has been taken to ensure that information contained in LWF's publications is true and correct at the time of publication, changes in circumstances after the time of publication may impact on the accuracy of this information.

Leave a reply

  *

  *

 


CAPTCHA Image

[ Change the image ]


*Required

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Compartmentation & Fire Severity - Part 10

    In LWF’s Fire Engineering blog series for Architects and others in the building design industry, we have been looking at the use of compartmentation to avoid the spread of fire. In part 9, the use of compartments with sprinkler systems was discussed and in part 10, we look at the potential severity of fires in enclosed spaces.The severity of a fire in an enclosed space is dependent upon factors such as heat leaving the...

    Read more...

  • Fire Safety for Healthcare Premises - Sprinklers - Part 44

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 43 of this series, we discussed cavity barriers and those areas where they are not practical for use, for fire safety reasons. In part 44, we move on to discuss the use of sprinklers in healthcare buildings. Sprinklers are not a requirement for patient areas of healthcare buildings...

    Read more...

  • Facilities Management & Fire Safety - Fire Safety Engineering - Part 1

    In LWF’s blog series for those who work in Facilities Management or who have an interest in or responsibility for fire safety, we were looking at fire safety training. In Part 1 of this series, however, we begin to review the subject of fire safety engineering. While most people reading on this subject could work out what fire safety engineering is, from the title, LWF will start by looking at the history of fire safety...

    Read more...

  • Fire Engineering Design and Risk Assessment - Compartmentation & Sprinklers - Part 9

    In LWF’s fire engineering blog series for Architects and others in the building design business, we have been looking at compartmentation and how can be used both in prescriptive and fire engineered solutions. In part 8 of this series, the provision of a fire safety strategy for a building was discussed and in part 9, we move onto how compartmentation and sprinklers work together.The effectiveness of sprinkler systems at controlling fires has had a...

    Read more...

  • Fire Safety for Healthcare Premises - Cavity Barriers and Sprinklers - Part 43

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 42 of this series, we looked at how cavity barriers should be installed in uninterrupted concealed spaces or cavities and also some exceptions to the rules. In part 43, we will continue looking at the use of cavity barriers in healthcare buildings.There are some instances where cavity...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..

Site map | Web development London