The Building Regulations 2010

The requirements of Regulation 38 of the Building Regulations 2010 are those formerly covered under Regulation 16b and relate to the fire safety information to be provided by the person carrying out work. This requirement has been around for a number of years however there is still confusion with regards to what is required to demonstrate compliance and often the standard of information provided varies greatly.

Introduction

Regulation 38 applies to a building that is erected or extended, or has undergone a material change of use, and where the Regulatory Reform (Fire Safety) Order (RR(FS)O) applies to that building or extension. For these buildings Regulation 38 requires that fire safety information be provided to the Responsible Person, as defined under the RR(FS)O, to assist them in fulfilling their duties in respect to the fire safety for the building.

The information provided should contain details of all fire safety precautions and design assumptions to a level of accuracy which is suitable to allow the effective ongoing maintenance and operation of the building. Information should be provided no later than the date of completion or first occupation of the building and Local Authorities and Approved Inspectors should not provide completion certificates or final notices until they are reasonably satisfied that Regulation 38 has been complied with.

The exact nature and detail of the information required to comply with the requirements of Regulation 38 will depend upon the complexity and nature of the building; and a ‘case by case’ approach is recommended within the guidance. It may be that this ‘case by case’ approach has lead to the inconsistency we see today in the standard of information provided.

Why It’s Important

The way a building has been designed plays an important part in the way it is then used and the design assumptions made can often restrict the use of a building or its ability to be effectively used for a purpose it was not designed for. This is true for the structural, architectural and services design and is equally the case for fire safety. Understanding the assumptions and key components of the design can be vitally important in being able to effectively manage the ongoing fire safety in the building. This is particularly important where buildings utilise fire engineering designs based upon compensatory features and/or management requirements. A failure to understand the fire safety design for a building could result in inappropriate use of the building and increased life safety risks should a fire occur.

The fire safety information required by Regulation 38 should also inform future fire risk assessments and allows the building owners/users to identify where changes to the building arrangements may affect the fire safety precautions. 

What Information Should Be Provided?

Guidance on the type of information which should be provided to comply with Regulation 38 is given in Appendix G of Approved Document B – Volume 2 (ADB). The ADB guidance is divided into two parts giving recommendations on the type of information required for ‘Simple’ and ‘Complex’ buildings.

For simple buildings the guidance recommends that only basic information is required. This information could take the form of a detailed as built plan of the building showing locations of the fire safety precautions in place, such as:

 ·         Means of Escape & Signage

·         Compartmentation & Fire Doors

·         Automatic Fire Detection & Emergency Lighting

·         Fire Service Provisions & Fire Fighting Equipment

·         Sprinklers & Smoke Control Systems

·         Hazard Areas

Any assumptions relating to the maintenance and management of the fire safety precautions should also be identified.

For complex buildings a more detailed record of fire precautions and fire strategy should be provided. This information will not only include as built drawings detailing all of the passive and active fire precautions in the building; but also information relating to any assumptions and analysis that has been conducted as part of the design. Design restrictions on the use of the building, fire safety management assumptions and procedures must be identified and understood.

BS9999 recommends that compilation of a Fire Safety Manual be started during the design stages of a project and progressed until it can be handed over to the Responsible Person on completion of the project. The intention is that this would then provide a valuable record of the design process and the decisions/compromises that have been made.

From our experiences both as Fire Engineers involved in the design of new buildings as well as Fire Risk Assessors; it is often the case that very little information is transferred to the occupier or that what is handed over is in an unordered state that is difficult to follow and is of no real value to those that would use it.

The types of documents and what they get called can vary depending on the project and what has been asked for by the Approving Authority, as a minimum we would recommend that most medium to large developments be provided with a fully developed Fire Strategy, As Built Fire Plans, a Preliminary or Pre-occupation Fire Risk Assessment as well as design documents and maintenance schedules for all fire safety systems in the building. This information then forms the basis for the Fire Safety Manual for the building. 

With an ever increasing number of engineered buildings and new construction technologies being developed it becomes even more important that the requirements of Regulation 38 be complied with and that the standard of information provided to the occupiers/Responsible Person is of a high standard.

This bulletin has been written by Richard Sherwood BEng (Hons)

 

Subscribe to our fire safety blogs

Bulletins
Email Format
* indicates required

FIRE SAFETY BLOGS

  • Fire Engineering Design and Risk Assessment - Firefighting & The Fire Service - Part 18

    In LWF's Fire Engineering blog series for Architects and others involved in building design, we have been looking at firefighting. In part 17, we began to look at how firefighting is undertaken by the Fire Service and their objectives and modes of operation when arriving at a fire. In part 19, tactical firefighting is discussed.While the general objectives of tactical firefighting were given in the last blog, there are various methods used by firefighters...

    Read more...

  • Fire Safety for Healthcare Premises - Open-sided Car Parks - Part 52

    In LWFs blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 51 of this series, we were looking at the potential for fire spread from one area of a building to another through external surfaces, before moving on to begin to look at the necessary arrangements for car parks. In part 52, we continue on that theme by considering...

    Read more...

  • Facilities Management & Fire Safety - Calculating RSET - Part 9

    In LWFs blog series for those who work in Facilities Management or who have an interest in or responsibility for fire safety we have been looking at fire safety engineering. In part 8, we looked at how ASET (Available Safe Egress Time) is calculated and how this should always be more than the RSET (Required Safe Egress Time). While ASET involves a series of calculations relating to fire growth and the building itself, RSET, also...

    Read more...

  • Fire Engineering Design and Risk Assessment - Firefighting & The Fire Service - Part 17

    In LWF’s fire engineering blog series for Architects and others in the business of building design, we have been looking at firefighting. In part 16, we discussed first-aid firefighting by the occupancy and the use of hose reels to do so. In part 17, we will begin to look at firefighting from the point of view of the Fire Services.The particular objectives of the Fire Service in a given situation will be decided upon...

    Read more...

  • Fire Safety for Healthcare Premises - External Fire Spread - Part 51

    In LWF’s blog series for healthcare professionals, the aim is to give information on best practice of fire safety in hospitals and other healthcare premises. In part 50 of this series, we discussed the potential for external fire spread including calculating unprotected areas and consideration of the surfaces of external walls and roofs. In part 51, we continue looking at external fire spread, starting with junctions of different elements.At the junction of wall and...

    Read more...

Case Studies

The Wohl Neuroscience Institute - Fire Safety, Strategy & Engineering
Key Facts: Client: King’s Clinical Neuroscience Institute Project Manager: MACE Ltd Designers: Devereux Architects/Allies and Morrison Approximate Size: 7,400m2 Description of the Project:...

Read more..

General Bulletins

Fire - The External Risk
When we consider fire safety, our focus is normally from within, what can we do to prevent the occurrence of fire and how we can limit its damage.  Whilst this is the correct stance to take, we m...

Read more..

Technical Bulletins

Evacuation Modelling - Factor in Human Behaviour
Evacuation of buildings can be analyzed in different ways. Approved Document B (ADB) which provides guidance on meeting the requirements of the England and Wales Building Regulations with regard to fi...

Read more..